D-R 800 Dust Concentration Monitor
|
PRODUCT DESCRIPTION
The D-R 800 Dust Concentration Monitor by the DURAG Group is ideal for emission control in industrial plants. The D-R 800 is a continuous in-situ measuring device and the measuring principle of the D-R 800 provides greater independence as velocity and electrical loading of the dust particles do not have any influence. The D-R 800 is a simple one-side stack mounting device and even thick walls are not problem for installation because only one hole of 70mm diameter is needed for flange monitoring.
The measuring device on the D-R 800 works on the principle of scattering light in forward direction and this physical principle explains the high sensitivity of this device. The collimated and modulated light beam of a Laser Diode crosses the measuring volume and the collected ‘stray light’ is proportional to dust concentration and is transferred via a special optical fibre to a receiver diode. There it is processed by a highly sensitive circuit to give the final measurement value.
The D-R 800 Dust Concentration Monitor has no moving parts in the stack which will ensure the extended lifetime of the instrument. The programming can be via the control display directly at the measuring device or comfortably from a PC via bus interface.
|
PRODUCT SPECIFICATIONS
|
Measuring principle
|
forward-scattering
|
Measuring range
|
0-10 mg/m3 up to 0-200 mg/m3 depending on kind of dust
|
Accuracy of measurement
|
2% of range end value
|
Relay outputs
|
four freely programmable zero voltage relay outputs with 24 VDC 2A switching power each
|
Analogue output
|
intensity of stray light
active current output, 0-20 mA
max. load 500 Ohm
Live zero 4 mA
after gravimetric calibration
dust concentration in mg/m3
|
Bus interface
|
Modbus
|
Inputs
|
2 freely programmable digital inputs
|
Integration of measuring value
|
1-1800 s freely adjustable
|
check cycle
|
0.1 to 48 h in 0.1 h steps
|
Channel Parameter
|
|
Permissible ambient temperature
|
-200C to +500C
|
Max. exhaust temperature
|
2200C
|
Min. exhaust temperature
|
>above gas dew point
|
Channel pressure
|
-50 to +10 hPa
|
Channel wall width
|
max. 400 mm
|
Electrical Data
|
|
Power supply
|
85-264 VAC, 47-63 Hz
|
Power consumption
|
50 W (system incl. purge air fan)
|
Mechanical Data
|
|
Measuring lance
|
1000 [600] x 160 x 160 mm ca. 7 [6] kg
|
Connection unit
|
380 x 300 x 210 mm approx. 13 kg
|
Protection class
|
IP 65
|
Laser protection class
|
II
|
|
|
Extensive descriptions of these units with specifications, setting instructions, dimensions and connection plans are available upon request.
|
HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au