Lear Siegler Australasia

CEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack Emissions

Model 410i CO2 Analyser

Model 410i CO2 Analyser Click here to enlarge image
Click here for Product Data Sheet

PRODUCT DESCRIPTION

The Thermo Scientifics range of iSeries gas analysers have by far and away the least requirement for maintenance of any gas analysers on the market today and are built for reliable continuous duty field gas detection.

The Model 410i CO2 Analyser is designed to monitor and report CO2 stack gas levels using either straight extractive sampling or dilution sampling by way of optical filter technology. The gas detection scheme uses optically fixed band pass interference filters and quantum detection to analyse the gas stream, leading to a superior level of performance and reliability. Add to that, an expanded ambient temperature operating range and these instruments provide excellent performance over a wider range of concentrations.

This state-of-the-art gas analyser offers features such as an Ethernet port as well as flash memory for increased data storage. Ethernet connectivity provides efficient remote access, allowing the user to download measurement information directly from the instrument without having to be on-site.

You can easily program soft-keys to allow you to jump directly to frequently accessed functions, menus or screens and the larger interface screen can display up to five lines of measurement information while the primary screen remains visible.

Click here to download the 410i CO2 Data Sheet

Click here to download the 410i O2 Data Sheet

PRODUCT SPECIFICATIONS

Preset Ranges

Standard: 0-200, 500, 1000, 2000, 5000, and 10000 ppm
High Level: 0-0.5, 1, 2, 5, 10, 20, 25%

Custom Ranges

Standard: 0-200 to 10000 ppm
High Level: 0-0.5 to 25%

Zero Noise

Standard: 0.5 ppb RMS (60 second averaging time)
High Level: 20 ppm RMS (60 second average time)

Minimum Detectable Limit

Standard: 1 ppm
High Level: 40 ppm

Zero Drift (24 hour)

+/-1.0 ppm

Span Drift (24 hour)

+2.0% of reading

Response Time

90 seconds (30 second average time)

Precision

+/-1.0% of reading

Linearity

+/-1.5% of span (at concentrations of 10% to 100% of span)

Sample Flow Rate

1.0 liter per minute

Operating Temperature

+50C to +450C

Power Requirements

100 vac, 115 vac, 220-240 vac +/-10% @ 275W

Size and Weight

16.75”(W) x 8.62”(H) x 23”(D), 39 lbs. (17.7 kg)

Outputs

Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Outout (optional)

Inputs

16 Digital Inputs (standard), 8 0-10vdc Analog Inputs (optional)


LSA Sales and Support Contact Us Today!

HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au