Lear Siegler Australasia

CEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack Emissions

Gas Sample Probe SP2000H

Gas Sample Probe SP2000H Click here to enlarge image
Click here for Product Data Sheet

PRODUCT DESCRIPTION

The M & C Products Gas Sample Probe SP2000H is used for continuous extraction of gases from dust loaden, high temperature and/or humid processes. The sample probes are designed for easy installation, reliable operation and trouble free maintenance.

The design offers little or no stagnant space external to the process and is easily mountable. The probes are designed so that changing a filter element does not involve the use of tools and in this operation neither the sample probe tube nor sample line need to be removed, thus avoiding contamination of the clean gas path and maintaining the integrity of the system.

The sample tube can be cleaned, washed or rodded-out from outside the process and the special design of the heating element permits controlled heating of the complete filter housing, including the mounting flange up to 1800C. This ensures reliable operation external to the process preventing the temperature falling below the dew-point.

PRODUCT SPECIFICATIONS

Protective cover

no

Degree of protection

IP54 EN60529

Filter housing material

Stainless steeel 316Ti*

Sealing materials

FPM* /7aT** = PTFE /H320** = graphite

Probe flange sealing material

Novapress

Insitu probe tube/prefilter

Optional

Sample pressure max.

0,4-6 bar* abs., /7aT**= 2 bar abs., /HP** = 25 bar abs.

Ambient temperature

20 0C to +180 0C

Filter chamber volume

120 cm3

Filter element, porosity

S-2K150= Ceramic*, 2micron, /F-0, 1GF150= Glass fibre**, 0,1 micron, /FW= Spun glass**

Sample gas outlet connection

1x 1/4" NPTi* tube connectors ø 6, 8 or 10 mm** /H320**= 6 mm

Backflush/Test gas connection

1/4“ NPTi* /R**, /H320**= tube ø 6 mm

Mounting flange

DN65 PN6-B, SS316Ti* >DN or ANSI possible** /HP** = DN50 PN25

Weight

7 kg*

* Standard
** Options
*** In case of higher ambient temperatures use option PT100 (Part No. 20S9025) or thermocouple Fe-CuNi respectively Ni-CrNi (Part No. 20S9027 resp. 20S9028) instead of the thermostate controller. Then, an additional electronic temperature controller (see data sheet 2-5.1) is necessary.

LSA Sales and Support Contact Us Today!

HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au