Lear Siegler Australasia

CEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack Emissions

Model 15i HCl Analyser

Model 15i HCl Analyser Click here to enlarge image
Click here for Product Data Sheet

PRODUCT DESCRIPTION

The Thermo Scientifics range of iSeries gas analysers have by far and away the least requirement for maintenance of any gas analysers on the market today and are built for reliable continuous duty field gas detection.

The Model 15i HCl Analyser measures the amount of Hydrogen Chloride in the ambient air using gas filter correlation technology. The Model 15i is based on the principle that Hydrogen Chloride (HCl) absorbs infrared radiation at a wavelength of 3.4 microns. Because infrared absorption is a nonlinear measurement technique, it is necessary for the instrument electronics to transform the basic analyser signal into a linear output.

Ethernet connectivity provides efficient remote access, allowing the user to download measurement information directly from the instrument without having to be on-site.

Easily programmable shortcut-keys allow you to jump directly to frequently accessed functions, menus or screens. The larger interface screen can display measurement information status while the viewing menu and operation screens.

PRODUCT SPECIFICATIONS

Preset Ranges

0-5, 10, 20, 50, 100, 200, 500, 1000, 2000, and 5000 ppm
0-10, 20, 50, 100, 200, 500, 1000, 2000, 5000, and 7500 mg/m3

Custom Ranges

0-5 to 5000 ppm
0-10 to 7500 mg/m3

Zero Noise

0.1 ppm RMS (5 minute averaging time)

Lower Detectable Limit

0.20 ppm

Zero Drift (24 hour)

+/- 0.2 ppm

Span Drift (24 hour)

+/-2% full scale

Response Time

120 seconds (30 second average time)

Precision

+/-0.1 ppm

Linearity

+/-2% full scale < 1000 ppm, +/- 5% full scale >1000 ppm

Sample Flow Rate

1.0 liters/min. nominal

Operating Temperature

50C - 450C

Power Requirements

100 vac, 115 vac, 220-240 vac +/-10% @ 275W

Size and Weight

16.75"(W) x 8.62"(H) x 23"(D), 49 lbs.
425 mm (W) x 219 mm (H) x 584 mm (D), 22.2 kg

Outputs

Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Output (optional)

Inputs

16 Digital Inputs (standard), 8 0-10vdc Analog Inputs (optional)


LSA Sales and Support Contact Us Today!

HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au