Lear Siegler Australasia

CEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack Emissions

Model 43i SO2 Analsyer

Model 43i SO2 Analsyer Click here to enlarge image
Click here for Product Data Sheet

PRODUCT DESCRIPTION

The Thermo Scientific range of iSeries gas analysers have by far and away the least requirement for maintenance of any gas analysers on the market today and are built for reliable continuous duty field gas detection.

Using pulsed fluorescence technology this analyser measures the amount of sulphur dioxide in the air and the pulsing of the U.V. source lamp serves to increase the optical intensity whereby a greater U.V. energy throughput and lower detectable SO2 concentration are realised. Reflective bandpass filters, as compared to commonly used transmission filters, are less subject to photochemical degradation and more selective in wavelength isolation. This results in both increased detection specificity and long term stability.

Ethernet connectivity provides efficient remote access, allowing the user to download measurement information directly from the instrument without having to be on-site.

You can easily program soft-keys to allow you to jump directly to frequently accessed functions, menus or screens and the larger interface screen can display up to five lines of measurement information.

PRODUCT SPECIFICATIONS

Preset Ranges

0-0.05, 0.1, 0.2, 0.5, 1, 2, 5, and 10 ppm
0-0.2, 0.5, 1, 2, 5, 10, 20, and 25 mg/m3

Extended Ranges

0-0.05, 1, 2, 5, 10, 20, 50 and 100 ppm
0-2, 5, 10, 20, 50, 100, 200, and 250 mg/m3

Custom Ranges

0-0.05 to 10 ppm
0-0.2 to 250 mg/m3

Zero Noise

1.0 ppb RMS (10 second averaging time), 0.5 ppb RMS (60 second averaging time), 0.25 ppb RMS (300 second averaging time)

Lower Detectable Limit

2.0 ppb (10 second averaging time), 1.0 ppb (60 second averaging time), 0.5 ppb (300 second averaging time)

Zero Drift (24 hour)

Less than 1 ppb

Span Drift (24 hour)

+/-1%

Response Time

80 seconds (10 second average time)
110 seconds (60 second average time)
320 seconds (300 second average time)

Precision

1% of reading or 1 ppb (whichever is greater)

Linearity

+/-1% full scale < 100ppm

Sample Flow Rate

0.5 liters/min. (standard)
1 liter/min. (optional)

Interferences (EPA levels)

< lower detectable limit except for the following:
NO < 3 ppb, M-Xylene < 2 ppb, H2O < 2% of reading

Operating Temperature

200C - 300C

Power Requirements

100 vac, 115 vac, 220-240 vac +/-10% @ 165W

Size and Weight

16.75"(W) x 8.62"(H) x 23"(D), 48 lbs. (21.8 kg)

Outputs

Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Outout (optional)

Inputs

16 Digital Inputs (standard), 8 0-10vdc Analog Inputs (optional)


LSA Sales and Support Contact Us Today!

HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au