Lear Siegler Australasia

CEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack EmissionsCEMS / Stack Emissions

CSS Compact Gas Conditioning Unit

CSS Compact Gas Conditioning Unit Click here to enlarge image
Click here for Product Data Sheet

PRODUCT DESCRIPTION

The M & C gas conditioning units CSS and CSS-3 are compact, rack mountable, low maintenance, self monitoring and completely equipped units suitable for standard applications.

This, at last, makes the usual time consuming procurement of individual components and assembly superfluous. With an option 4-position rotary switch more than one calibration gas can be selected.

Great importance has been placed on the maintenance friendly design and required maintenance can be easily accessed via a removable front sub-panel without dismantling the entire system.

The gas conditioning system in the 19inch plug-in unit can be supplied for operation at 230V or 115V AC mains supply.

PRODUCT SPECIFICATIONS

Inlets and max. gas flow**

1x 140 Nl/hr (CSS Version) 1x 350 Nl/hr (CSS-3 Version)

Outlets incl. flowmeters

2x à 70 Nl/hr (CSS Version) 2x à 250 Nl/hr (CSS-3 Version)

Gas pressure

0,7 to 1,2 bar abs.

Sample gas inlet temperature**

max. 150 0C

Sample gas inlet dewpoint**

max. 80 0C

Sample gas outlet dewpoint

+5 0C

Ambient temperature**

+5 0C to +40 0C

Total cooling capacity at +25 0C ambient temperature

max. 50 kJ/hr (CSS Version) max. 90 kJ/hr (CSS-3 Version)

Storage temperature

-25 0C to +65 0C

Relative humiditiy

<80%

Ready for work

approx. 10 min

Gas filter

glassfibre, porosity 0,1 μm

Housing

19'' rack mounting 6U, depth 350 mm, color RAL 7032

Degree of protection

IP 20-EN 60529

Tube connections

G 1/4 i -DIN ISO 228/1*

Power supply

230V, 48-62Hz, 150VA or 115V, 48-62Hz, 150VA (CSS Version) 230V, 48-62Hz, 250VA or 115V, 48-62Hz, 250VA (CSS-3 Version)

Electrical equipment standard

EN 61010

Electrical connections

power terminals max 4 mm2, 4x PG13,5 Alarm- / control signals 15-pin Sub-D connector

Status signal

cooler temperature, liquid alarm, flow alarm

Satus alarm contact, contact rating

potential free changeover contact, max. 24V, 1A

Test gas inlets

2 solenoid valves, actuated manually orby external switch* (optional +3 pcs)

Material of sample contacting parts

PVDF, glass, FPM, Novoprene®, PTFE

Weight

approx. 15 kg (CSS Version) approx. 16,5 kg (CSS-3 Version)

* = Standard
** = Maximum values in technical data must be rated in consideration of total cooling power at 25 0C ambient temperature.
# = Standard for max. 20 m heated sample line at 110W /m.

LSA Sales and Support Contact Us Today!

HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au