Lear Siegler Australasia

Model 600 FID Total Hydrocarbon Analyser

Model 600 FID Total Hydrocarbon Analyser Click here to enlarge image
Click here for Product Data Sheet

PRODUCT DESCRIPTION

The Model 600 FID analyser by California Analytical Instruments utilises the principle of Flame Ionisation Detection to determine the total hydrocarbons within a gaseous sample. The analysers exhibit superior sensitivity and response time. The gaseous sample can be exhaust gases from an internal combustion engine, a combustion process or a VOC abatement system.

This product line is designed around a state of the art 16 bit microprocessor, with 16 digital inputs, 16 digital outputs, 16 analogue inputs and 4 analogue outputs. The analyser can be manually operated from the keypad or remotely via TCP/IP, RS-232C communications and discrete inputs.

The analyser display includes screen presentation of all analyser alarms and four levels of password protection are provided.

PRODUCT SPECIFICATIONS

Detector

Flame Ionization Detection

THC Ranges

Four User Definable ranges from 0-3 to 0-30,000 ppm

Response Time

90% Full Scale in 1.5 Seconds

Resolution Detection Limit

10 ppb

Repeatability

Better than 0.5% of Full Scale

Linearity

Better than 1% of Full Scale

Noise

Less than 1% of Full Scale

Zero & Span Drift

Less than 1% of Full Scale per 24 Hours

Zero & Span Adjustment

Via front panel, TCP/IP or RS-232

O2 Effect

Less than 3% with H2 / He Fuel

CH4 Effect

Less than 1.15

Flow Control

Electronic Proportional Pressure Controller

Sample Flow Rate

Typically 2.0 LPM (Consult factory for other flow rates)

Fuel Requirements

40/60 H2/He (120CC/min) or 100% H2 (60cc/min) Specify at time of order

Fuel Inlet Pressure

25 psig

Air Requirements

Less than 1ppm THC Purified or Synthetic air (220cc/min for H2/He; 300 cc/min for H2)

Air Inlet Pressure

25 psig

Fuel & Air Control

Electronic Proportional Pressure Controller

Readout

As ppm CH4 or C3H8

Analog Outputs

0-1,0-5,0-10, VDC, 4-20mA (selectable)

Communications

RS232 and TCP/IP

Discrete Alarms/Control

15 definable, optically isolated solid state relays (60 VDC max @ 600 mA max)

Diagnostics

Burner Temperature, Sample/Fuel/Air Pressures, Flow Rates and EPC Control Voltages

Keypad Displays

Factory Settings, TCP/IP Address, Passwords (4), Scalable Analog Output Voltages, Full Scale Range Select, Auto Cal Times

Special Features

Auto Ranging, Auto Calibration (adjustable through internal clock), Data Archiving

Ignition

Local, Remote or Automatic

Display

3” x 5” Back lit LCD

Sample Temperature

50°C, Non-condensing

Ambient Temperature

5 to 40°C

Ambient Humidity

Less than 90% RH (Non-condensing)

Warm-Up Time

1 Hour (Typical)

Fittings

1/4 Inch Tube

Power Requirements

115 VAC/60 Hz or 230 VAC/50 Hz;

Dimensions

5¼ H x 19 W x 23 D (Inches)

Weight

35 lbs.


LSA Sales and Support Contact Us Today!

HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au