Lear Siegler Australasia

Personal MonitoringPersonal MonitoringPersonal Monitoring

GasPoint

GasPoint Click here to enlarge image
Click here for Product Data Sheet

PRODUCT DESCRIPTION

The GasPoint transmitter by BW Technologies provides continuous monitoring of hazardous gases through advanced sensor technology and microcontroller based operation. The GasPoint transmitter can accept any GasPoint sensor type: electrochemical, catalytic or IR (infrared). All plug-in sensor assemblies are field interchangeable and a daily sensor integrity test is automatic and monitors sensor operation and length of time the sensor has been in service.

The GasPoint transmitter is equipped with three 5-amp relay contacts, two gas alarm relays (low/high) and fault alarm and two backlit alphanumeric LCDs will advise all environmental and gas hazard conditions as well as instrument and sensor status.

PRODUCT SPECIFICATIONS

Monitor

3-wire, 4-20 mA gas transmitter with advanced microcontroller-based circuitry

Power input

12 to 32 volts DC

Output current

Normal Operation: Isolated linear 4-20 mA output
Calibration Mode: Steady 3 mA (auto reset to normal operation)
Fault Mode: 2 mA signal (and less)

Power consumption

Toxic Versions: 40 mA at 24 VDC
Combustible Version: 100 mA at 24 VDC
Relays: 50 mA per relay at 24 VDC

Sensors

Plug-in, smart sensors

Detection type

Combustible gases: catalytic or IR; Toxic gases and Oxygen: electrochemical

Self-test

Automatic daily self-test of sensor integrity and sensor life

Relative humidity

5 to 95% RH non-condensing

Drift

Zero: <5% per year; Span: <10% per year

Calibration

Non-intrusive, via pushbutton Auto zero and auto span

Displays

Two backlit liquid crystal displays
LCD 1 3-digit continuous readout of the gas present (ppm, % LEL or %v/v)
LCD 2 Alphanumeric diagnostic status display

Alarm setpoints

Two setpoints: user-selectable

Relay Contacts

Three SPDT relays; 5 amps at 250 VAC
LOW/HIGH: Field selectable for normally energized/de-energized and latching/ non-latching
FAULT: Normally energized and non-latching

Transmission Ranges

Relay contacts not considered. (For ranges with relays see manual.)

Controls

Calibration: Non-intrusive via external pushbutton
Alarm Setpoints: Simple up/down pushbuttons with LCD readout of setpoints

Physical

Size: 6.8 x 7 x 4.3 inches / 17 x 17.8 x 10.8 cm (approx.)
Weight: 4.85 lb. / 2.2 kg (approx.)

Transmitter

Nema 4, explosion-proof, anodized aluminum enclosure with mounting fl anges

Sensor

Stainless steel enclosure

Warranty

Instrument: 2 years non-prorated; Sensor: 2 years full replacement warranty


LSA Sales and Support Contact Us Today!

HEAD OFFICE
Unit 5A, 2 Resolution Drive
Caringbah, NSW 2229
Australia
Ph: 61 2 9531 5444
Fax: 61 2 9531 5411
sales@learsiegler.com.au