PRODUCT DESCRIPTION
The Thermo Scientific Model 5014i Beta Continuous Particulate Monitor is an automated, continuous, ambient particulate monitor that utilises beta attenuation technology in combination with the established iSeries platform design. The Model 5014i Beta Continuous Particulate Monitor is accurate and reliable and also rack mountable.
This continuous particulate monitor utilises the combined real-time principles of the beta-attenuation, density and background beta rejection as the means towards a refined mass measurement of the collected aerosol. The air sample volume on this continuous particulate monitor is precisely controlled and accurately measured through a subsonic orifice.
The Model 5014i Beta Continuous Particulate Monitor can be configured to measure PM-10, PM-2.5, PM-1 or TSP. This state-of-the-art continuous particulate monitor also features Flash Memory for increased data storage, enhanced Ethernet connectivity, remote data access and iPort communication software.
|
PRODUCT SPECIFICATIONS
|
Source
|
Carbon-14 (C-14), < 3.7 MBq (< 100 μCi)
|
Measurement Range
|
0 to 1.0, 2.0, 3.0, 5.0, 10.0 mg/m3
0 to 100, 1,000, 2,000, 3,000, 5,000, 10,000 μg/m3
|
Minimum Detection Limit
|
6 μg/m3 (1/2 hour), 4 μg/m3 (1hour) 3 μg/m3 (3 hour), 1 μg/m3 (24-hour)
|
Resolution
|
0.1 μg/m3
|
Precision
|
±2.0 μg/m3 < 80 μg/m3, 4-5 μg/m3 > 80 μg/m3 (24-hour average)
|
Accuracy (for mass measurement)
|
± 5% using NIST-traceable mass foil set
|
Air Flow Rate
|
1m3/h (16.67L/min) measured across an internal subsonic orifice
|
Sample Flow Precision
|
±2% of measured value
|
Sample Flow Accuracy
|
< 5% of measured value
|
Mass Concentration
|
60 to 3,600 seconds and 24-hour
|
Data Output Rate
|
Every 1 second
|
Operating Temperature
|
860F - 1400F (300C - 600C). The unit must be weather protected within the range of 390F - 1220F (40C - 500C) An optional Complete Outdoor Enclosure provides complete weather protection
|
Non-condensing
|
95% RH inside 5014i
|
Output
|
RS232/RS485, TCP/IP, 10 Status relays and power fail indication (standard). 6 user defi ned analog outputs (0-100mV, 0-1, 0-5 or 0-10 Vdc), Six 0-20 or 4-20 mA isolated current output (optional)
|
Input
|
16 Digital inputs (standard), Eight 0 to 10 Vdc Analog inputs (optional), 8 User-defi ned Analog outputs (0-1 or 0-5 Vdc)
|
Power Requirements
|
100 - 240 VAC, 50-60 Hz Recommended
805 Watts (115V); 880 Watts (220-240V) Watts Maximum (instrument, heater & pump)
Pump 120 VAC/60 Hz: 4.25A; 240VAC/50Hz:2.25A
|
Physical Dimensions
|
16.75" (42.5cm) W x 23" (58.4cm) D x 8.62 (21.9cm) H
19" rack mountable with optional ears and handles
|
Weight
|
40 lbs. (19kg)
|
Protocols
|
C-Link, MODBUS TCP/IP, Gesytec (Bayern-Hessen), ESM Protocol, Streaming data and NTP (Network Time Protocol) protocols. Simultaneous connections from different locations over Ethernet
|
|